THIẾT BỊ GIAO TIẾP QUANG SOT-NP401S


Specification Model No. Descriptions Sample System Configuration Specifications Model SOT-NP401H/S□ SOT-NP403H/S□ SOT-NP801H/S□ SOT-NP803H/S□ Rated power voltage DC12/24V Ripple 100 mVp-p or less Power voltage used DC10 – 30V Ripple 100…

THIẾT BỊ GIAO TIẾP QUANG SOT-NP401S

    Liên hệ: 0393.665.382

    THÔNG TIN SẢN PHẨM

    Specification

    Model No. Descriptions

    Sample System Configuration

    Specifications

    Model
    SOT-NP401H/S□
    SOT-NP403H/S□
    SOT-NP801H/S□
    SOT-NP803H/S□
    Rated power voltage
    DC12/24V Ripple 100 mVp-p or less
    Power voltage used
    DC10 – 30V Ripple 100 mVp-p or less
    Consumable current
    60mA MAX
    Transmission distance
    0 – 1m
    0.1 – 3m
    0 – 1m
    0.1 – 3m
    Direction angle
    30°
    30°
    Transmitting points
    Input 4-bit/Output 4-bit
    Input 8-bit/Output 8-bit
    Transmission method
    Half-duplex 2-way and 1-way direction
    Detecting method
    Bit reverse any time comparison method
    Transmitting time
    15ms MAX (M/S mode) 20ms MAX (X mode)
    Projecting element
    Short-wave-length infrared LED
    Receiving element
    Photo transistor
    Modulation method
    Pulse modulation 45 KHz
    Input date points
    4 points
    8 points
    input model Photo-coupler insulation type (Sink input)
    Input signal Contact-point or Open collector
    Input voltage DC10 – 30V However, input voltage is the line-to-line voltage
    between EXT+V and IN
    Input current 4±0.5mA (in DC 24V) However, the residual voltage when turned On is below than 2V. The leakage current when turned Off is below than 0.5mA.
    Output date points
    4 points
    8 points
    Output model Non-insulation model Open collector output by NPN transistor (Sink Output)
    Load voltage DC4.5 – 30V
    Load current 100mA per point The residual voltage when output turned On Should be below than 1.5V and total load current Below than 500mA
    Indicators
    POW display: Lights up (red) when power is on
    CTL/TCD display: Lights up (red) when CTL input is on/lighted (green) when TCD input is on
    Lighted
    DT/RCV display: Lights up (red) during successful data reception/lighted (green) during stable optical reception
    IN display: Lights up (red) when data input is on
    OUT display: Lights up (green) when data output is on
    When the RCV display (green) is lighted , the DT display (red) will also be lighted .
    Connection
    With attached 1-m cable 18C × 0.14mm2 (AWG26)
    With attached 1-m cable 26C × 0.14mm2(AWG26)
    Ambient operating temperature
    -20 – +50°C No freezing temperatures allowed.
    Ambient operating humidity
    40 – 85% RH No condensation allowed.
    Ambient operating illumination
    4,000lx or less for incandescent and fluorescent lamps
    No externally disturbed light shall directly enter the receiver.
    Vibration resistance
    10 to 55Hz in frequency, 1.5mm in complex amplitude and 5minutes for sweep
    20 cycles in each of X, Y and Z directions
    Shock resistance
    500m/s2, 20 cycles in each of X, Y and Z directions
    Enclosure rating
    IP66
    Outside dimensions
    60mm (W) × 50mm (D) × 22mm (H)