RELAY OMRON MY2N 220/240 VAC


Product classification Monostable relays Coil ratings 220 VAC 4.8 mA (50 Hz) / 220 VAC 4.2 mA (60 Hz) / 240 VAC 5.3 mA (50 Hz) / 240 VAC 4.6…

RELAY OMRON MY2N 220/240 VAC

    Liên hệ: 0393.665.382

    THÔNG TIN SẢN PHẨM

    Product classification Monostable relays
    Coil ratings 220 VAC 4.8 mA (50 Hz) / 220 VAC 4.2 mA (60 Hz) / 240 VAC 5.3 mA (50 Hz) / 240 VAC 4.6 mA (60 Hz)
    Coil resistance 18790 Ω
    Operate voltage (Set voltage) 80 % max.
    Release voltage (Reset voltage) 30 % min.
    Max. voltage 110 % max. (of rated voltage)
    Power consumption Approx. 0.9 to 1.3 VA (60 Hz)
    Operating indicator LED
    Contact type DPDT
    Contact method Single
    Contact material Ag
    Contact rated load 220 VAC 5 A (Resistive load)
    220 VAC 5 A (Inductive load (cos φ= 0.4))
    24 VDC 5 A (Resistive load)
    24 VDC 5 A (Inductive load (L/R = 7 ms))
    Maximum switching voltage 250 VAC
    125 VDC
    Maximum switching current AC: 5 A
    DC: 5 A
    Failure rate 1 mA at 5 VDC (failure level: P Reference value) (Switching frequency of 120 operations per minute)
    Ambient temperature (Operating) -55 to 60 ℃ (with no icing or condensation)
    Ambient_humidity (Operating) 5 to 85%RH (with no icing or condensation)
    Contact resistance 50 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
    Operating time (Set time) 20 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored)
    Release time (Reset time) 20 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored)
    Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
    Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
    Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
    Dielectric strength Between coil and contacts: 2000 VAC (50/60 Hz 1 min)
    Between contacts of different polarity: 2000 VAC (50/60 Hz 1 min)
    Between contacts of same polarity: 1000 VAC (50/60 Hz 1 min)
    Vibration resistance (Destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
    Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
    Shock resistance (Destruction) 1000 m/s**2
    Shock resistance (Malfunction) 200 m/s**2
    Endurance (Mechanical) 50 million operations min. (switching frequency 18,000 operations/h)
    Endurance (Electrical) 500,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h)
    Protective structure Closed type (cover)
    Terminal structure Plug-in terminal
    Weight Approx. 35 g

    SẢN PHẨM CÙNG LOẠI

    Menu